GWS Ethernet connection: Difference between revisions
m (teisaldas lehekülje Ethernet connection pealkirja GWS Ethernet connection alla) |
No edit summary |
||
(One intermediate revision by the same user not shown) | |||
Line 1: | Line 1: | ||
Ethernet connection is used for configuring data concentrators like GW6, GWM, RTA<br /> | Ethernet connection is used for configuring data concentrators like GW6, GWM, RTA<br /> | ||
To establish connection with the device using Ethernet connection, | To establish connection with the device using Ethernet connection, configure settings in SSH window. '''SSH''' button opens '''SSH settings''' window, where communication parameters can be set. When parameters are set, '''Test''' button could be clicked to conform the connection. When Access granted line appears, connection is OK and user can save parameters by cliking '''OK'''. Red light next to SSH button should turn green. Connection with the device is established. Now user can read ('''R''') or write ('''W''') configuration from/to device. '''C''' is for cancelling.<br /> | ||
Parameters in the SSH settings window:<br /> | Parameters in the SSH settings window:<br /> |
Latest revision as of 07:52, 25 September 2017
Ethernet connection is used for configuring data concentrators like GW6, GWM, RTA
To establish connection with the device using Ethernet connection, configure settings in SSH window. SSH button opens SSH settings window, where communication parameters can be set. When parameters are set, Test button could be clicked to conform the connection. When Access granted line appears, connection is OK and user can save parameters by cliking OK. Red light next to SSH button should turn green. Connection with the device is established. Now user can read (R) or write (W) configuration from/to device. C is for cancelling.
Parameters in the SSH settings window:
User: | Username of the device (default: martem) |
IP: | IP address of the device (default addresses are for ETH0: 192.168.0.111) |
Password: | password of the device (default password is provided by Martem AS) |
Setup version: | GW6-e and GWM support only version 4 |
Putty: | Opens remote terminal |
Open Remote Terminal: | Opens remote terminal with log in parameters described in User, IP and Password string. |
Change password: | Enables user to change device password |
Test: | Test connection between PC and Telem device |
OK: | Saves the parameters and closes window |
Reboot: | Reboots the device |
R1: | Reset the device |
R2: | Reset and also clear memory buffers |
R3: | Reset and restore the default setup |
Any SSH client, e.g. Putty, can be used to connect with the device. Baudrate 115200bps is used. Necessary user names and passwords are provided by Martem AS.