= | = Info below not updated anymore, see redmine roadmap for latest data = | ||
<div style="padding: 5px; margin: 0.50em 0; background-color: #FFDDDD; border: thin solid #DDBBBB; overflow: hidden;"> | <div style="padding: 5px; margin: 0.50em 0; background-color: #FFDDDD; border: thin solid #DDBBBB; overflow: hidden;"> | ||
'''Warning:''' | '''Warning:''' | ||
Last update below was for 2.0.156 (03.04.2020) | |||
</div> | </div> | ||
= | = TELEM-AGC, TELEM-GW6e, TELEM-GWM53 and TELEM-GWM25 = | ||
== Recommended software == | |||
<div style="padding: 5px; margin: 0.50em 0; background-color: #FFDDDD; border: thin solid #DDBBBB; overflow: hidden;"> | <div style="padding: 5px; margin: 0.50em 0; background-color: #FFDDDD; border: thin solid #DDBBBB; overflow: hidden;"> | ||
'''Warning | '''Warning! GWS >= 2142 must be used''' | ||
</div> | </div> | ||
=== kernel4: === | |||
2.0.156-3e1f29e-k4 - GW6e VMX53/6DL, AGC 6DL/6UL | |||
2.0.156-3e1f29e-k4-03 - GWM VMX25/VMX53/6DL/6UL | |||
=== kernel2(pre 2014 devices): === | |||
2020.04.01-next-02-c8fd29a - GW6e ('''No IEC61850 Client''') | |||
== Firmware downgrade == | |||
<div style="padding: 5px; margin: 0.50em 0; background-color: #FFDDDD; border: thin solid #DDBBBB; overflow: hidden;"> | |||
'''Warning:''' | |||
* Downgrading firmware has never been supported. | |||
* It is possible to downgrade, but there are no guarantees. | |||
</div> | |||
== telem-app Changelog for kernel 4 == | |||
*2.0.156-3e1f29e-k4/2.0.156-3e1f29e-k4-03 (GWS 2142) | |||
: IEC61850 | IEC 61850 Client KEMA certified | |||
: IEC60870 | 104 Server KEMA certified | |||
: IEC60870 | 101UB Server fix AI event sent as normalized when implied float | |||
: IEC60870 | FIX AO subtype determination | |||
: IEC60870 | Fix DO/AO unknown COT | |||
: IEC60870 | 101B Server fix floating point subtype up | |||
: IEC60870 | Fix deact in client | |||
: IEC60870 | Fix multiple lower level addresses per device (fix #3450) | |||
Telem- | : IEC60870 | DO/AO fixes | ||
: OPC UA | OPC UA Server implementation | |||
Telem-GW6e: | : Api | Add cls.json to webserver (fix #3522) | ||
: Db | Fix backup import | |||
: Core | Boost 1.71 | |||
* | : Core | Sensor code safer | ||
: Core | Sensor objects have flags | |||
: Core | AGC SCL IO | |||
: ModBus | Mitigate offset in value<->data (fix #3462) | |||
: ModBus | Initial impl of 64 bit ai type (fix #3402) | |||
*2.0.141-3b46188-k4-02 Telem-GWM (GWS 2133) | |||
: Core | Fixed Control issues | |||
: Logging | PCAP feature | |||
*2.0.141-3b46188-k4 Telem-AGC, Telem-GW6e (GWS 2133) | |||
: Core | Fixed Control issues | |||
: Logging | PCAP feature | |||
*2.0.132-ddea1dd-k4-02 Telem-AGC, Telem-GW6e (GWS 2131) | |||
: Core | Fixed Select event loss issue | |||
: Logging | Improved logging | |||
*2.0.132-ddea1dd-k4-03 Telem-GWM (GWS 2131) | |||
: Core | Fixed Select event loss issue | |||
: Logging | Improved logging | |||
*2.0.82-288715d-k4 Telem-GW6e, Telem-GWM (GWS 2104) | |||
: Updates | Minor bug fixes | |||
*2018.02.08-linux_4-04-b7d1941 / 2018.02.08-next-02-1a34917 (GWS 2086) | *2018.02.08-linux_4-04-b7d1941 / 2018.02.08-next-02-1a34917 (GWS 2086) | ||
: Formula | Fix complex formulas not recalculating after after init | : Formula | Fix complex formulas not recalculating after after init | ||
Line 63: | Line 82: | ||
* 2017.10.31-linux_4-03-e9d281f / N/A k2 (GWS 2081b) | * 2017.10.31-linux_4-03-e9d281f / N/A k2 (GWS 2081b) | ||
: Formula | Integral expression rewrite to integral(@ai, @di) [https://phobos.martem.ee/redmine/issues/2848 #2848] | : Formula | Integral expression rewrite to integral(@ai, @di) [https://phobos.martem.ee/redmine/issues/2848 #2848] | ||
: Filter | Optimize lock usage between LatestValues and UpdateLatest | : Filter | Optimize lock usage between LatestValues and UpdateLatest | ||
== telem-app Changelog for kernel 2 == | |||
* 2018.02.08-next-02-1a34917 | |||
: Formula | Fix complex formulas not recalculating after after init | |||
: Other fixes | |||
* 2017.09.26-next-03-c81082e / 2017.09.26-linux_4-05-50ff00d (GWS 2079) | * 2017.09.26-next-03-c81082e / 2017.09.26-linux_4-05-50ff00d (GWS 2079) | ||
: '''HOTFIX''' IEC101/104 DO_FN | Fix: SCADA did not receive command status responses if DO_FN object configured for IED [https://phobos.martem.ee/redmine/issues/2877 #2871] | : '''HOTFIX''' IEC101/104 DO_FN | Fix: SCADA did not receive command status responses if DO_FN object configured for IED [https://phobos.martem.ee/redmine/issues/2877 #2871] |
Latest revision as of 10:11, 2 July 2021
Info below not updated anymore, see redmine roadmap for latest data
TELEM-AGC, TELEM-GW6e, TELEM-GWM53 and TELEM-GWM25
Recommended software
kernel4:
2.0.156-3e1f29e-k4 - GW6e VMX53/6DL, AGC 6DL/6UL
2.0.156-3e1f29e-k4-03 - GWM VMX25/VMX53/6DL/6UL
kernel2(pre 2014 devices):
2020.04.01-next-02-c8fd29a - GW6e (No IEC61850 Client)
Firmware downgrade
telem-app Changelog for kernel 4
- 2.0.156-3e1f29e-k4/2.0.156-3e1f29e-k4-03 (GWS 2142)
- IEC61850 | IEC 61850 Client KEMA certified
- IEC60870 | 104 Server KEMA certified
- IEC60870 | 101UB Server fix AI event sent as normalized when implied float
- IEC60870 | FIX AO subtype determination
- IEC60870 | Fix DO/AO unknown COT
- IEC60870 | 101B Server fix floating point subtype up
- IEC60870 | Fix deact in client
- IEC60870 | Fix multiple lower level addresses per device (fix #3450)
- IEC60870 | DO/AO fixes
- OPC UA | OPC UA Server implementation
- Api | Add cls.json to webserver (fix #3522)
- Db | Fix backup import
- Core | Boost 1.71
- Core | Sensor code safer
- Core | Sensor objects have flags
- Core | AGC SCL IO
- ModBus | Mitigate offset in value<->data (fix #3462)
- ModBus | Initial impl of 64 bit ai type (fix #3402)
- 2.0.141-3b46188-k4-02 Telem-GWM (GWS 2133)
- Core | Fixed Control issues
- Logging | PCAP feature
- 2.0.141-3b46188-k4 Telem-AGC, Telem-GW6e (GWS 2133)
- Core | Fixed Control issues
- Logging | PCAP feature
- 2.0.132-ddea1dd-k4-02 Telem-AGC, Telem-GW6e (GWS 2131)
- Core | Fixed Select event loss issue
- Logging | Improved logging
- 2.0.132-ddea1dd-k4-03 Telem-GWM (GWS 2131)
- Core | Fixed Select event loss issue
- Logging | Improved logging
- 2.0.82-288715d-k4 Telem-GW6e, Telem-GWM (GWS 2104)
- Updates | Minor bug fixes
- 2018.02.08-linux_4-04-b7d1941 / 2018.02.08-next-02-1a34917 (GWS 2086)
- Formula | Fix complex formulas not recalculating after after init
- 2018.01.12-linux_4-01-8b72574 / 2018.01.12-next-02-abe5e00 (GWS 2083)
- Formula | DB accessor thread optimisations
- Change Filter | Discard NaN values. Pass event with previous value and OVF bit
- IEC60870 | Event priority rework
- Core | Periodical GI improvements
- IEC61850 | Alstom P14 DI bug workaround #2916
- IEC61850 | Improve cmds #2925
- IEC101UB Slave | Improve varLenMsg parsing #2933
- IEC101/104 | Add debug messages to AO cmd
- Scale Filter | Fix AI scaling twice on lower device timeout #2930
- 2017.11.18-linux_4-01-87d4416 / 2017.11.18-next-01-9c9c97b (GWS 2081b)
- Build for all devices and kernels
- 2017.11.10-linux_4-01-8595646 / N/A k2 (GWS 2081b)
- Formula | Integral expression minor timing fix #2848
- IEC60870 | Fix device objects not sent with GI on 101-104 translation, only lower device objects #2908
- 2017.10.31-linux_4-03-e9d281f / N/A k2 (GWS 2081b)
- Formula | Integral expression rewrite to integral(@ai, @di) #2848
- Filter | Optimize lock usage between LatestValues and UpdateLatest
telem-app Changelog for kernel 2
- 2018.02.08-next-02-1a34917
- Formula | Fix complex formulas not recalculating after after init
- Other fixes
- 2017.09.26-next-03-c81082e / 2017.09.26-linux_4-05-50ff00d (GWS 2079)
- HOTFIX IEC101/104 DO_FN | Fix: SCADA did not receive command status responses if DO_FN object configured for IED #2871
- 2017.09.20-next-01-b162ac5 / 2017.09.20-linux_4-02-2436894 (GWS 2079)
- Modbus | Polling sequence fix (AI was polled less) #2871
- Modbus | Communication on port stalls if any device has no valid objects #2873
- 2017.09.13-next-01-800b844 / 2017.09.13-linux_4-feature-integral-expression-01-930dddd (GWS 2079)
- Modbus | fix AO scaling #2807
- 2017.09.11-linux_4-01-7ee57df (GWS 2079)
- Telem Master | support 18 (was 17) CMD address
- Formula | AI Formula -> AO CMD fix
- 2017.08.08 (GWS 2079)
- WebServer | Correctly set persistant pages
- WebServer | Fix user credentials
- GWM IO-Board IFR feature #2841
- Modbus | Fix polling delay #2839
- WebServer | fix sprintf buffer size
- Channel | Channel optimisations
- Core | Fix thread pool manager (TaskIoBase)
- WebServer | replace deprecated functions
- IEC101/104 | add DST bit functionality #2833
- 2017.06.09-next-01-353984f (GWS 2079)
- Reset 2 Clear Buffers fix #2814
- 2017.04.17-next-08-af772c0
- Logging | Buffered logging
- 2017.04.05-next-07-65a2e5a
- SPA-Bus | Timesync: send 3x short ts and 3x long ts
- 2017.04.03-next-01-557bc40
- Core | Fix spontaneous events after GI on initial successful lower lever device initialisation (#2793)
- Core | Refix sending reset cmds from TDC
- 2017.03.21-next-03-b5cc1d0
- Optimisation (Webserver) | Avoid websocket connection duplicates
- Optimisation (app close) | make WebSocketAppender thread safe
- Optimisation (app close) | fix numerous potential places that cause segfault on app close
- Build | build with latest GNU compilers (v 6).
- IEC60870 | IEC103 events without timetag fix
- Formula | fix Formula output controller trying to execute DO CMD until it succeeds.
- Formula | fix Formula when using another formula object as argument, that is further down the list in GWS (#2794)
- 2017.01.31-next-01-3eefdf3
- Optimisation | all telem-app optimisations merge
- IEC60870 | fix control state conatiner in IEC 101 for GWM with IO board
- Protocol | control state logger improved logs
- 2016.12.02-next-01-a502dae Don't use on VMX25 Don't use on GWM with DO
- SPA-Bus | ABB SPAC330C feature
- IEC61850 | 101 support multiple DO with same v-addresses (multiple rows with same v-addresses)
- 2016.11.23-next-01-0260688 Don't use on VMX25 Don't use on GWM with DO
- IEC61850 | 103 support multiple DO with same v-addresses (multiple rows with same v-addresses)
- 2016.11.15-next-02-b43c191 Don't use on VMX25 Don't use on GWM with DO
- Localization | Change non-ASCII characters to * in Port and Device commments (#2751)
- 2016.11.15-next-01-5dc3aa7 Don't use on VMX25 Don't use on GWM with DO
- IEC61850 | 104 event loss after disconnect fix (#2725)
- 2016.11.04-next-02-3a9808a Don't use on VMX25 Don't use on GWM with DO
- Database | Set object flags to Invalid instead of NotTopical on startup
- SPA-Bus | objects not going not topical on Timeout fix
- SPA-Bus | potential segfault fix
- 2016.10.08-next-01-c91481f
- IEC-101,104 | GI Switch per object (requires GWS 6.1.0.2068+)
- IEC-101,104 | DO can have 2 downstream addresses (like 1/2)
- 2016.10.05-next-06-bb13408
- Protocol | Remove event sorting by time when sending to upstream Retract 2016.09.19-next-01-c0127ec additions
- Protocol | upstream events faster
- IEC-103 | Micom workarounds
- 2016.10.03-next-02-1cb7e5f
- Protocol | time sync interval from XML implementation
- SPA-Bus | fix event time is it is assumed that event came before last minut change
- SPA-Bus | request L, then poll once and change device
- SPA-Bus | delay next device for 50ms after timesync
- 2016.09.26-next-01-91e178f
- SPA-Bus | Scaling fix (#2689)
- Logging | raw port log in ASCII
- 2016.09.23-next-01-00fde37 (#2721)
- SPA-Bus | event can have effect on multiple objects
- 2016.09.19-next-01-c0127ec (#2693)
- Protocol | Events are sent upstream in order of the lowest timetag Retracted in 2016.10.05-next-06-bb13408
- 2016.09.08-next-01-526b387
- IEC | fix IEC 101 UB variable length frame bigger than 255 issue
- Formula | fix double masking in fomrula ???
- 2016 year device fw and GWS 6.1.0.2064
- NoMainLog for formula
- 2016.08.25-next-03-b45984d
- Modbus | ai_bit DI type
- Modbus | DO: define ON and OFF address in the same cell
- improved logging
- SPA-Bus | poll all
- 2016.08.23-next-01-d702b81
- Logging | fine tuned device initialization logging. Old device oriented (GW6, RTA)
- fix DO Inversion bug (#2702)
- 2016.05.11-next-02-e02304a
- SPA-Bus | minor fixes for rare nack and timeout cases
- SPA-Bus | commented out object sorting
- 2016.05.04-next-01-64e4492
- SPA-Bus | protocol subtype for ABB ref542
- SPA-Bus | poll L messages after 5 object poll requests
- SPA-Bus | mode 1 implementation: poll multiple objects in one request (#2635)
- SPA-Bus | DO: define ON and OFF address in the same cell
- SPA-Bus | channel number definable for every event number (#2637)
- SPA-Bus | event numbers for Intermediate and Error states
- SPA-Bus | fallback fixes (#2658)
- SPA-Bus | switch between devices on same port after L message
- SPA-Bus | define incoming DI object type (Dobule/Single) (#2654)
- SD card licence implementation (#2592)
- remove non ASCII characters from object comment (#2577)
- [22.03.2016]
- 1-wire segfault on bing temp. change fix (#2640)
- [11.03.2016]
- IEC-104 object type priorities fix. Big amounts of AI data prevented DI events propagation. (#2625)
- [23.02.2016]
- webserver v2 IE11 not working fix
- [10.02.2016]
- NEW_DATABASE formulas numerous fixes
- ADDED LIB TO PROJECT: fastformat
- logging optimizations using fastformat. VMX25 up to 10x faster
- [16.12.2015]
- license additions to support no modem GWM (#2565)
- [17.11.2015]
- longer interval for some tasks
- SyncDatabaseToFile 2s->5s
- ProcessRetranslation 10ms->500ms
- explicitly sync db backup to non-volatile memory only on reset/low-power.
- [06.11.2015]
- IEC-101/104 QOC (Qualifier of command) implementation (#2495)
- [05.11.2015]
- AI scaling rewrite (COMPATIBILITY BREAK)
- virtual I/O object pair crash app if invalid address fix (#2572)
- [30.10.2015]
- web-server v2 shows device eth info (#2532)
- [16.10.2015]
- fix SPA-Bus polling delay (#2546)
- [14.10.2015]
- IEC DO_FN | IEC101/104 type 105 C_RP_NA_1 (reset process) implementation (#2498)
- IEC DO_FN | IEC101/104 GI command via DO implementation (#2499)
- [13.10.2015]
- zero value deadband implementation (#2536)
- [24.09.2015]
- DO/AO stops IEC-101 messages fix for devices using old database (#2527)
- allow bigger conf size for NEW_DATABASE devices
- SETUP_WITH_XML_BIN_SIZE 500KB->1.5MB
- EXTRACTED_XML_SETUP_SIZE 6MB->20MB
- [07.09.2015]
- GWM IO-board + 101-104 conversion not working fix (#2520)
- [25.08.2015]
- IEC-61850 mem-leak/consumption fixes
- remove BIT_INVALID_TIME from BIT_VALUE_CHANGED_MASK
- [22.08.2015]
- devie booting time nnX times faster (#2472)
kernel 4 Changelog since 2017
- 2017.08.22
- fix GW DNS service
- 2017.02.10
- fix sftp access
- fix configuring SSH from GWS
kernel 2 Changelog since 2013
- 2017.07.12
- log4cxx | patch for socket appender
- pack_logs | pack modem history log
- init | fix spamming logs (S48, S61m S99)
- fw_update | fix errors on fw update (S12usb)
- init | fix spamming logs on stop (S37)
- modem | fix handling huawei modems
- WebServer | Restore syslog options
- 2017.04.17-next-08-af772c0
- update | Additional checks in post-update scripts for GWM rev.1 FTDI IO Board
- 2017.04.05-next-07-65a2e5a
- pack_logs now packs all existing console logs and eeprom log if exists
- 2017.04.03-next-03-49423a0
- fix enabling peripheral power on startup with usbs suspended (fixes old GWM53 FTDI IO Board)
- 2017.01.31-next-01-3eefdf3
- remove cifs support from vmx25 kernel. No more space left on device.
- 2016.11.04-next-01-51a8c40 Don't use on VMX25 Don't use on GWM with DO
- IEC-101,104 | DO invert fix sending ACK with inverted address
- init | S99phy fix toggling LAN power and wait longer
- init | fix starting modem then date is in the start of epoch (1970)
- init | Script fixes for fresh device with linux default time
- 2016.10.19-next-09-3e89e79 Don't use on VMX25 Don't use on GWM with DO
- CIFS support in kernel for network mounts !! This change bricks VMX25. Removed from VMX25 after 30.01.2017
- 2016.10.08-next-01-c91481f
- init | optimizations for FTDI eeprom software
- init | getwdbootmsg fixes
- init | major refactoring. Performance & readability fixes
- 2016.10.03-next-02-1cb7e5f
- Syslog | Add possibility to change loglevel and remote server port
- ntp | do not restart ntp if only gps is configured (2711)
- ntp | avoid frequent ntp restarts by other scripts
- modem | avoid frequent modem restart by multiple scripts (only 1 restart allowed per one minute).
- modem | rewrite telit modem reseting as described in telit manual
- init | fix socat sometimes creating /dev/tty* as ordinary file instead of letting modem driver to do it.
- init | performance fixes
- 2016.07.28-next-06-3d426af
- Device CPU frequency lowered from 1.2GHz to 1.0GHz | Improved ssh key generation and license cheking
- [11.02.2016]
- physical interface checker script implementation
- [10.02.2016]
- ADDED LIB TO PROJECT: fastformat
- [26.01.2016]
- GWS 'Get logs' acquires n+1 more rotating logs
- [23.07.2015]
- ADDED LIB TO PROJECT: boost_chrono to source.pro (websocketpp 0.6.0 depends)
- [08.06.2015]
- application segmentation fault fix (2429)
- [27.04.2015]
- DI fallback bug fix (2312)
- [23.04.2015]
- DI object double inversion bug fix (2345)
- [21.04.2015]
- no flags not working fix (2194)
- [24.03.2015]
- Periodical GI implementation for all protocols (every 5th minute of hour)
- [16.03.2015]
- Telem Master protocol implementation
- [29.01.2015]
- IEC-10x ASDU transfer implementation
- [30.10.2014]
- IEC-101B serial communication improvements
- [23.10.2014]
- No main/CSV log for individual objects
- 2014.01.13-next-01-2a5df30
- added uINT16 (unsigned 16bit integer) in modbus protocol. (also update gws)
- 2014.01.09-next-01-2fae2d9
- fix IEC104 bug in GW6
- 2014.01.07-next-01-8180155
- fix fallback (GW6e and GWM), "NONE" protocol, device "in use"=no, FP-to-normalised conversion, deadband issues, IEC104 bug in GW6e. (also update gws)
- 2013.11.18-next-04
- fix IEC-104 bug (mark data as NT if connection to IEC-104 slave is lost and parameter "failed query count for disabling contr." > 1)
- 2013.11.12-next01
- fix AO feedback bug in GW6 and RTA-A
- 2013.11.04-next
- time invalid flag for GW6 and RTA-A (also requires DSP/RTC software update!)
- 2013.10.24-next
- IEC101-to-IEC104 short time to long time conversion
- 2013.09.16-next07
- configurable COT=2 Bytes for IEC101b
- 2013.09.09-next01
- configurable COT=2 Bytes for IEC101ub
- 2013.07.12-next02
- write modem status to /var/log/modem.st
Old Devices RTA-A and GW6
Latest Firmware
Last fw version GW6: 2015.12.11-develop-01-104a492
Last fw version RTA-A M502: 2015.12.11-develop-01-104a492
Last fw version RTA-A M501: 2015.12.11-develop-01-104a492
GW6-1206
- Timezones for ports and system.
Userland
- dnsmasq
- iperf
Kernel
- iptables: Support for -m limit. For instance:
/usr/sbin/iptables -t filter -A INPUT -p tcp --dport 2404 --sport 1024:65535 -m state --state NEW -m limit --limit 25/minute --limit-burst 100 -j ACCEPT
- tc: Basic support. For instance:
/sbin/tc qdisc del dev eth0 root 2> /dev/null > /dev/null /sbin/tc qdisc del dev eth0 ingress 2> /dev/null > /dev/null /sbin/tc qdisc add dev eth0 handle ffff: ingress /sbin/tc filter add dev eth0 parent ffff: protocol ip prio 1 u32 match ip src 0.0.0.0/0 police rate 512kbit burst 1m drop flowid :1 /sbin/tc qdisc add dev eth0 root handle 1: cbq avpkt 1000 bandwidth 20mbit /sbin/tc class add dev eth0 parent 1: classid 1:1 cbq rate 512kbit allot 1500 prio 1 bounded isolated /sbin/tc class add dev eth0 parent 1: classid 1:2 cbq rate 512kbit allot 1500 prio 2 bounded isolated /sbin/tc class add dev eth0 parent 1: classid 1:3 cbq rate 512kbit allot 1500 prio 3 bounded isolated /sbin/tc filter add dev eth0 parent 1: protocol ip prio 16 u32 match ip protocol 1 0xff flowid 1:1 /sbin/tc filter add dev eth0 parent 1: protocol ip prio 1 u32 match ip sport 80 0xffff flowid 1:2 /sbin/tc filter add dev eth0 parent 1: protocol ip prio 1 u32 match ip sport 22 0xffff flowid 1:3
GW6-1204
- IEC104: Respond to message sent to broadcast ASDU (0xFFFF)
- IEC-62056: mask incoming data with 0x7F (ASCII protocol)
- Serial ports: Suppress echo
- WebPage: Long awaited by all interenet browsers the favicon.ico
GW6-1202
- IEC104: Fix possible event loss on ethernet cable removal.
- Formula: Do not generate control event, on first successful calculation.
GW6-1200
- Firmware version readable through internal WebServer
- Fix possible event loss when lots of changes arrive for one input.
- GPRS-modem protocol: if connection to internet is lost, all TCP client connections are closed
- IEC104: force long-time format
GW6-1198
- IEC101/103 Unbalanced Master: add feature polling delay
- When sending a control operation over IEC103 channel with many devices. Speed up receiving of control response.
GW6-1196
- Connection loss with RTC-board does not result in watchdog reset.
- Symptoms: device will reset after 20 seconds of running.
- Device will write system boot count and application start count to console.log. Latest values can be found in /var/local/telem/stats
RTA-A-1192
- RTA-A: possible to define DO object to clear annunciator LED 's
- Modbus Master: Fix receiving of negative 16bit normalized values.
GW6-1190
- Added new update pack type app-only.
- Note: This update pack type should only be used on device with SW version 1190 or later.
- This update will not overwrite system files - less chance for bricking if something goes wrong (accidental power loss or reset).
- Generate /etc/network/interfaces file once after receiving new setup.
- New protocol type IEC ^ Setup
- Only reading and writing of device setup is allowed on this Port.
- Allows faster booting of device with a lot of unused Up-channel ports.