GW6e Conformace Test
		
		
		
		Jump to navigation
		Jump to search
		
GW6e Conformace Test
| Implemented transmission system | |
|---|---|
| Unbalanced system | - | 
| Network configuration | |
| Point-to-point | - | 
| Multidrop | - | 
| PHYSICAL LAYER | |
| Transmission speed | |
| 1200 bit/s | - | 
| 2400 bit/s | - | 
| 4800 bit/s | - | 
| 9600 bit/s | - | 
| 19200 bit/s | - | 
| LINK LAYER | |
| Link transmission procedure | |
| Unbalanced transmission | - | 
| Address field of the link | |
| One octet | - | 
| Two octets | - | 
| Frame length | |
| Unstructured | - | 
| Common address of ASDU | |
| One octet | - | 
| Information object address | |
| Two octets | - | 
| Three octets | - | 
| Unstructured | - | 
| Cause of transmission | |
| One octet | - | 
| SELECTION OF STANDARD ASDUS | |
| Process information in monitor direction | |
| <1> := Single-point information | - | 
| <2> := Single-point information with time tag | - | 
| <3> := Double-point information | - | 
| <4> := Double-point information with time tag | - | 
| <5> := Step position information | - | 
| <6> := Step position information with time tag | - | 
| <9> := Measured value, normalised value | - | 
| <10> := Measured value, normalised value with time tag | - | 
| <11> := Measured value, scaled value | - | 
| <12> := Measured value, scaled value with time tag | - | 
| <13> := Measured value, short floating point value | - | 
| <14> := Measured value, short floating point value with time tag | - | 
| <30> := Single point information with full time | - | 
| <31> := Double point information with full time | - | 
| <32> := Step position information with full time | - | 
| <34> := Measured value, normalised value with full time | - | 
| <35> := Measured value, scaled value with full time | - | 
| <36> := Measured value, short floating point value with full time | - | 
| Process information in control direction | |
| <45> := Single command | - | 
| <46> := Double command | - | 
| <47> := Regulating step command | - | 
| <58> := Single command with time tag CP56Time 2a | - | 
| <59> := Double command with time tag CP56Time 2a | - | 
| <60> := Regulating step command with time tag CP56Time 2a | - | 
| System information in monitor direction | |
| <70> := End of initialisation | - | 
| System information in control direction | |
| <100> := Interrogation command | - | 
| <102> := Read command | - | 
| <103> := Clock synchronisation command | - | 
| <105> := Reset process command | - | 
| <106> := Delay acquisition command | - | 
| File Transfer | |
| <120> := File ready | - | 
| <121> := Section ready | - | 
| <122> := Call directory, select file, call file, call section | - | 
| <123> := Last section, last segment | - | 
| <124> := Ack file, ack section | - | 
| <125> := Segment | - | 
| <126> := Directory | - | 
| BASIC APPLICATION FUNCTIONS | |
| Station Initialisation | |
| Station initialisation for unbalanced systems | - | 
| Remote initialisation | - | 
| Data acquisition by polling | |
| first procedure: “request user data class 1”. | - | 
| second procedure: “request user data class 2”. | - | 
| Read procedure | |
| for Unbalanced systems C_RD_DATA | - | 
| Cyclic data transmission | |
| cyclic data transmission | - | 
| Acquisition of events (for unbalanced systems) | |
| case 1: spontaneous data is NOT available | - | 
| case 2: spontaneous data is available | - | 
| General Interrogation | |
| Interrogation procedure for unbalanced systems | - | 
| Interrogation procedure for events arrive between interrogation responses | - | 
| Global | - | 
| group 1 | - | 
| group 2 | - | 
| Clock synchronisation | |
| Clock synchronisation for unbalanced systems | - | 
| Command transmission | |
| Command procedure for unbalanced systems | - | 
| Direct single command transmission | - | 
| Direct double command transmission | - | 
| Direct regulation command transmission | - | 
| Select and execute single command | - | 
| Select and execute double command | - | 
| Select and execute regulation command | - | 
| ACTTERM is used | - |