Telem-RTA-XA: Difference between revisions
(Uus lehekülg: 'RTA-XA is a new extended version of RTA-A. RTA-XA has 2 HW versions - ver.A (main) and ver.B (optional). Versions have different front panels. Both have 32 LED's for main digi...') |
No edit summary |
||
Line 1: | Line 1: | ||
RTA-XA is a new extended version of RTA-A. | '''RTA-XA is a new extended version of RTA-A.''' | ||
RTA-XA is based on Voipac's i.MX25 Controller. | |||
RTA-XA has 2 HW versions - ver.A (main) and ver.B (optional). | RTA-XA has 2 HW versions - ver.A (main) and ver.B (optional). | ||
Line 13: | Line 15: | ||
* Concentrated data acquisition and control using different communication protocols | * Concentrated data acquisition and control using different communication protocols | ||
5 serial ports (one RS232 full-modem galvanically isolated, one RS232/485 (4-wire), one RS232, one RS232/GPS and one RS485 (2-wire) galvanically isolated port. | |||
Ethernet | |||
* Analog signal measurements | * Analog signal measurements | ||
Six quasi-differential inputs with following HW factory configurable parameters: | |||
1. Ground - real (power source low "-" level) for unipolar measurement or virtual (approx. +1.5V) for bipolar measurement. | |||
2. ADC input range 0...3V. | |||
3. Current measurement with shunt resistors 100 ohms (+-10 or 20 mA range) or 200 ohms (+-5 or 10 mA range). | |||
4. Possibility to configure one input for voltage measurement (with restrictions). | |||
'''Note: Not all HW configure possibilities have firmware and configuration SW support!''' | |||
* Digital contact and acquisition of pulse counting info | * Digital contact and acquisition of pulse counting info | ||
32 main digital inputs + 2 additional (on the controller board), all optically isolated. | |||
* On/Off control functions | * On/Off control functions | ||
8 x 2 digital outputs (dry contacts). | |||
* "Execute" signal output (dry contact) | |||
* Time synchronization using GPS | * Time synchronization using GPS | ||
* Analog outputs for control (optional) | * Analog outputs for control (optional) | ||
2 outputs 4...20 mA | |||
* IFR output (dry contact) | |||
* Power input from 10 to 72Vdc | |||
* Temperature sensor (1-wire) input. |
Revision as of 12:46, 5 April 2012
RTA-XA is a new extended version of RTA-A.
RTA-XA is based on Voipac's i.MX25 Controller.
RTA-XA has 2 HW versions - ver.A (main) and ver.B (optional). Versions have different front panels.
Both have 32 LED's for main digital inputs status indication, one bi-color LED for device status indication and one acknowledge button.
Ver.B has six additional multi-purpose buttons with their status LED's.
Features
- Concentrated data acquisition and control using different communication protocols
5 serial ports (one RS232 full-modem galvanically isolated, one RS232/485 (4-wire), one RS232, one RS232/GPS and one RS485 (2-wire) galvanically isolated port.
Ethernet
- Analog signal measurements
Six quasi-differential inputs with following HW factory configurable parameters:
1. Ground - real (power source low "-" level) for unipolar measurement or virtual (approx. +1.5V) for bipolar measurement.
2. ADC input range 0...3V.
3. Current measurement with shunt resistors 100 ohms (+-10 or 20 mA range) or 200 ohms (+-5 or 10 mA range).
4. Possibility to configure one input for voltage measurement (with restrictions).
Note: Not all HW configure possibilities have firmware and configuration SW support!
- Digital contact and acquisition of pulse counting info
32 main digital inputs + 2 additional (on the controller board), all optically isolated.
- On/Off control functions
8 x 2 digital outputs (dry contacts).
- "Execute" signal output (dry contact)
- Time synchronization using GPS
- Analog outputs for control (optional)
2 outputs 4...20 mA
- IFR output (dry contact)
- Power input from 10 to 72Vdc
- Temperature sensor (1-wire) input.